(Türkler) Ege A.Ekdal E.Karali T.Can N.2024-07-222024-07-22200713504487http://akademikarsiv.cbu.edu.tr:4000/handle/123456789/19235The kinetic parameters of a newly prepared tissue-equivalent, highly sensitive thermoluminescent detector, Li2 B4 O7 : Cu, Ag, P of sintered pellets have been calculated. Thermoluminescence (TL) glow curves of Li2 B4 O7 : Cu, Ag, P samples after β-irradiation showed peaks at about 384 and 446 K with a heating rate of 1 K s- 1. The kinetic parameters, namely activation energy (E) and frequency factor (s) associated with the main glow peak (446 K) of Li2 B4 O7 : Cu, Ag, P have been determined using isothermal decay (ID) and peak shape (PS) methods. The activation energies obtained by ID and PS methods are calculated to be 1.12 and 1.13 eV (mean), respectively. The frequency factors obtained by both methods are 7.61 × 1011 and 3.53 × 1011 s- 1 (mean), respectively. Results obtained using both methods are compared and discussed. © 2007 Elsevier Ltd. All rights reserved.EnglishActivation energyDosimetersHeating rateKinetic parametersLithium compoundsFrequency factorsHighly sensitive thermoluminescent detectorsIsothermal decay (ID)Peak shape (PS)ThermoluminescenceDetermination of thermoluminescence kinetic parameters of Li2 B4 O7 : Cu, Ag, PArticle10.1016/j.radmeas.2007.06.008