Yentur, EALuleci, NTopcu, IDegerli, KSurucuoglu, S2025-04-102025-04-101098-7339http://hdl.handle.net/20.500.14701/35694Background and Objectives: Epidural space infection is a potential complication of epidural catheter placement. in this study, we investigated the incidence of epidural needle and catheter contamination after skin surface disinfection with 10% povidone-iodine (PI). Methods: Sixty seven patients having surgery under epidural anesthesia were enrolled in this prospective study. After preparation with 10% PI, skin swab cultures were taken from the site of catheter insertion. Epidural needles were cultured immediately after epidural catheters were placed. Catheters were removed at 48 hours and 2 to 3 cm of the distal tips were cultured as well. Results: Fifty-six skin swabs, 52 epidural needles, and 48 catheters were cultured. Although only 3.5% (2) colonization was observed on skin surface cultures, 34.6% (18) of the epidural needles and 45.8% (22) of the catheters were colonized. No systemic or local infection was observed. Conclusion: Our results suggest that despite skin surface disinfection with PI, there is still significant risk for contamination of needles and catheters during epidural catheterization.EnglishIs skin disinfection with 10% povidone iodine sufficient to prevent epidural needle and catheter contamination?Article; Proceedings Paper1532-8651