Repository logo
  • English
  • Català
  • Čeština
  • Deutsch
  • Español
  • Français
  • Gàidhlig
  • Italiano
  • Latviešu
  • Magyar
  • Nederlands
  • Polski
  • Português
  • Português do Brasil
  • Srpski (lat)
  • Suomi
  • Svenska
  • Türkçe
  • Tiếng Việt
  • Қазақ
  • বাংলা
  • हिंदी
  • Ελληνικά
  • Српски
  • Yкраї́нська
  • Log In
    Have you forgotten your password?
Repository logoRepository logo
  • Communities & Collections
  • All Contents
  • English
  • Català
  • Čeština
  • Deutsch
  • Español
  • Français
  • Gàidhlig
  • Italiano
  • Latviešu
  • Magyar
  • Nederlands
  • Polski
  • Português
  • Português do Brasil
  • Srpski (lat)
  • Suomi
  • Svenska
  • Türkçe
  • Tiếng Việt
  • Қазақ
  • বাংলা
  • हिंदी
  • Ελληνικά
  • Српски
  • Yкраї́нська
  • Log In
    Have you forgotten your password?
  1. Home
  2. Browse by Author

Browsing by Author "Celik A.G."

Now showing 1 - 2 of 2
Results Per Page
Sort Options
  • No Thumbnail Available
    Item
    Avoidable thermodynamic inefficiencies evaluation of a sewage water source heat pump system
    (Inderscience Publishers, 2023) Celik A.G.; Hepbasli A.
    The performance of a sewage water source heat pump system is assessed through conventional/enhanced exergy-based methods in this present study. The experimental data used in the analyses are based the cooling mode. According to the conventional-based results, the condenser has the lowest exergy efficiency. Beside this, the enhanced exergy-based analysis results show the sewage water heat exchanger should be considered as the most significant component as it has the highest avoidable exergy destruction rate in the whole system and takes the improvement priority. Based on the enhanced exergy analysis, 56% of the total exergy destruction belongs to the avoidable part. Copyright © 2023 Inderscience Enterprises Ltd.
  • No Thumbnail Available
    Item
    Assessment of exergy-based performance and sustainability indicators of a sewage water source heat pump system
    (Inderscience Publishers, 2024) Celik A.G.; Hepbasli A.
    Exergy analysis helps identify the amount and the positions of exergy losses in any system along with its main components. To achieve sustainability, these irreversibilities should be diminished. This study aims at presenting the exergetic-based performance of a sewage water source heat pump system based on experimental data. Initially, the exergetic performance assessments are carried out and then the exergetic performance results are evaluated using exergy-based sustainability indicators. The SWSHP system had the values for exergetic efficiency 57.77%–63.81% and overall sustainability index 2.31–2.72, respectively. Eight other exergy-based indicators are applied to determine and compare the most impacted component among the others. Copyright © 2024 Inderscience Enterprises Ltd.