Browsing by Author "Durmaz F."
Now showing 1 - 2 of 2
Results Per Page
Sort Options
Item Economic Analysis of the Photovoltaic Installation Use Possibilities in Farms; [Analiza Ekonomiczna Mozliwości Zastosowania Instalacji Fotowoltaicznej W Gospodarstwach Rolnych](De Gruyter Open Ltd, 2020) Kwaśniewski D.; Akdeniz C.; Durmaz F.; Kömekçi F.The aim of the study was to conduct an economic analysis of the possibilities of using photovoltaic (PV) installations in selected farms. Two selected online PV calculators were used for the analysis. The research included 15 farms located in the Małopolskie Province. For a PV installation estimated using Calculator 1, Hewalex, the payback period ranged from 5.5 to 7 years for the 40% subsidy option and from 9 to 11 years without the subsidy, respectively. On the other hand, the payback period estimated with the use of the SmartekDom calculator ranged from 6 to 8 years for the option with 40% subsidy. However, without the subsidy, the period ranged from 7 to even 13 years. © 2020 Dariusz Kwaśniewski et al., published by Sciendo.Item The effect of inhaled corticosteroids in the outcomes of community-acquired pneumonia: ICCAP study (TURKCAP Database)(Blackwell Publishing Ltd, 2020) Baha A.; Kokturk N.; Bahcecioglu S.N.; Yapar D.; Aksakal N.; Gündüz C.; Tasbakan S.; Sayiner A.; Coskun A.S.; Durmaz F.; Cilli A.; Celenk B.; Kılınc O.; Salman S.; Hazar A.; Tokgoz F.Objective: We aimed to investigate the effect of inhaled corticosteroids (ICS) in the outcomes of community-acquired pneumonia (CAP), as well as to determine if ICS usage is exist among the risk factors for mortality in those patients. Materials and Methods: In this retrospective cross-sectional multicentre study, 1069 hospitalised CAP patients were investigated using CAP Database of Turkish Thoracic Society (TURKCAP Database). The patients were divided into two groups, depending on their ICS use. The data were analysed by appropriate statistical methods. Results: 172 (75.8%) of the 227 patients who were on ICS had COPD and 37 (16.3%) had asthma. There were fewer patients with fever among ICS-users compared to non-ICS users (P = 0.013), and less muscle pain (P = 0.015) and fewer GIS symptoms (P = 0.022). No statistically significant difference was found between ICS use/ type of ICS and the duration of hospitalisation (P = 0.286). The multivariate regression analysis showed that patients using ICS had lower body temperature and, less crackles/bronchial sound. In the multivariate logistic regression model lung cancer (OR: 6.75), glucose (OR: 1.01) and CURB-65 (OR: 1.72) were significantly associated with mortality in the CAP patients. ICS usage were not found to be associated with mortality. Conclusion: The use of ICS by the patients with CAP admitted to the hospital is not independently related with any radiological pattern, hospitalisation duration and mortality. ICS usage may diminish fever response and may suppress the findings of crackles and/or bronchial sounds. This needs further confirmation. © 2020 John Wiley & Sons Ltd