Repository logo
  • English
  • Català
  • Čeština
  • Deutsch
  • Español
  • Français
  • Gàidhlig
  • Italiano
  • Latviešu
  • Magyar
  • Nederlands
  • Polski
  • Português
  • Português do Brasil
  • Srpski (lat)
  • Suomi
  • Svenska
  • Türkçe
  • Tiếng Việt
  • Қазақ
  • বাংলা
  • हिंदी
  • Ελληνικά
  • Српски
  • Yкраї́нська
  • Log In
    Have you forgotten your password?
Repository logoRepository logo
  • Communities & Collections
  • All Contents
  • English
  • Català
  • Čeština
  • Deutsch
  • Español
  • Français
  • Gàidhlig
  • Italiano
  • Latviešu
  • Magyar
  • Nederlands
  • Polski
  • Português
  • Português do Brasil
  • Srpski (lat)
  • Suomi
  • Svenska
  • Türkçe
  • Tiếng Việt
  • Қазақ
  • বাংলা
  • हिंदी
  • Ελληνικά
  • Српски
  • Yкраї́нська
  • Log In
    Have you forgotten your password?
  1. Home
  2. Browse by Author

Browsing by Author "Prokić M."

Now showing 1 - 2 of 2
Results Per Page
Sort Options
  • No Thumbnail Available
    Item
    Effect of heating rate on kinetic parameters of β-irradiated Li 2B4O7:Cu,Ag,P in TSL measurements
    (Institute of Physics Publishing, 2007) Ege A.; Ekdal E.; Karali T.; Can N.; Prokić M.
    The effect of heating rate on the thermally stimulated luminescence (TSL) emission due to the temperature lag (TLA) between the TSL material and the heating element has been investigated using Li2B4O 7:Cu,Ag,P dosimetric materials. The TLA becomes significant when the material is heated at high heating rates. TSL glow curves of Li 2B4O7:Cu,Ag,P material showed two main peaks after β-irradiation. The kinetic parameters, namely activation energy (E) and frequency factor (s) associated with the high temperature main peak of Li2B4O7:Cu,Ag,P were determined using the method of various heating rates (VHR), in which heating rates from 1 to 40 K s-1 were used. It is assumed that non-ideal heat transfer between the heater and the material may cause significant inconsistency of kinetic parameter values obtained with different methods. The effect of TLA on kinetic parameters of the dosimeter was examined. © 2007 IOP Publishing Ltd.
  • No Thumbnail Available
    Item
    Reply to comments on 'effect of heating rate on kinetic parameters of β-irradiated Li2B4O7:Cu,Ag,P in TSL measurements'
    (2009) Ege A.; Tekin E.; Can N.; Prokić M.
    We appreciate the opportunity to respond to comments regarding the paper published by Ege et al (2007 Effect of heating rate on kinetic parameters of β-irradiated Li2B4O7:Cu,Ag,P in TSL measurements Meas. Sci. Technol. 18 889). We would like to thank the authors for taking the time to tell us about their opinion, but unfortunately we do not agree with them completely. In the article presented by Kumar and Chourasiya some comment is advanced to the analysis of the glow curves measured with different heating rates, presented in our recent study. According to our study, the area under the glow curve decreases with increasing heating rate in TL-temperature plots due to the quenching effects. Contrary to this, Kumar and Chourasiya suggest that this decrease is due to the normalization process. Here we hope to clarify any confusion regarding our published study. © 2009 IOP Publishing Ltd.

Manisa Celal Bayar University copyright © 2002-2025 LYRASIS

  • Cookie settings
  • Privacy policy
  • End User Agreement
  • Send Feedback