Browsing by Subject "Drug Implants"
Now showing 1 - 2 of 2
Results Per Page
Sort Options
Item Intravitreal Dexamethasone Implant in Retinitis Pigmentosa-related Cystoid Macular Edema(Lippincott Williams and Wilkins, 2018) Mansour A.M.; Sheheitli H.; Kucukerdonmez C.; Sisk R.A.; Moura R.; Moschos M.M.; Lima L.H.; Al-Shaar L.; Arevalo J.F.; Maia M.; Foster R.E.; Kayikcioglu O.; Kozak I.; Kurup S.; Zegarra H.; Gallego-Pinazo R.; Hamam R.N.; Bejjani R.A.; Cinar E.; Erakgün E.T.; Kimura A.; Teixeira A.Purpose: To report the clinical outcome after intravitreal dexamethasone implant in patients with retinitis pigmentosa and cystoid macular edema. Methods: Multicenter retrospective case series of eyes with retinitis pigmentosa and cystoid macular edema that underwent intravitreal dexamethasone implant. Primary outcome measures were best-corrected visual acuity in LogMAR and central macular thickness. Statistical analyses used two-tailed comparison with Wilcoxon signed-rank test. Results: There were a total of 45 eyes from 34 patients with a mean age of 32.7 years (range 16-57) and mean follow-up of 15.5 ± 13.0 months. At Month 3 after the first injection, mean initial best-corrected visual acuity improved from 0.61 ± 0.38 (20/81) to 0.37 ± 0.16 (20/47) (P = 0.012), whereas mean central macular thickness (m) decreased from 506 ± 288 m to 311.7 ± 71.6 m (P < 0.001) and mean intraocular pressure increased from 15.7 ± 2.3 mmHg to 19.8 ± 11.0 mmHg (P = 0.01). Fourteen eyes had multiple injections (1-7 reinjections) at a mean interval of 6 months. Treatment effect was durable with multiple injections, but with seven eyes developing visually significant cataracts. Conclusion: Best-corrected visual acuity improved up to 4 months in around half of the eyes. Eyes that benefited the most were pseudophakic, steroid nonresponsive, with large initial central macular thickness, and profuse fluorescein dye leakage. © Ophthalmic Communications Society, Inc.Item Anterior chamber migration of ozurdex implants(Turkish Ophthalmology Society, 2020) Kayıkcıoğlu Ö.; Doğruya S.; Sarıgül C.; Mayalı H.; Kurt E.We present patient characteristics and follow-up results of cases with anterior chamber dexamethasone implant migration. The common feature of all six presented cases was vitrectomized eyes. Four of the patients had sutured intraocular lens (IOL) implantation due to complicated cataract surgery, one had combined retinal detachment surgery with sutured IOL implantation, and one had vitrectomy for diabetic intravitreal hemorrhage cleaning and uncomplicated cataract surgery. Anterior chamber implant migration caused corneal edema in all cases and elevated intraocular pressure in three cases. In two cases, the dexamethasone implant was directed into the vitreous cavity after maximum pupillary dilation and corneal manipulation with cotton tip applicator with the patient in reverse Trendelenburg position. There was no other complication until dexamethasone implant degradation, with clear cornea at final examination. In two cases, the implant was removed from the anterior chamber by aspiration, but keratoplasty surgery was planned due to endothelial cell loss and persistent corneal edema during follow-up. In the last two cases, the dexamethasone implant was redirected into the vitreous chamber with a 23-gauge catheter and anterior chamber maintainer but they migrated into the anterior chamber again. In one of these patients, the implant was aspirated by catheter and corneal transplantation was performed due to corneal edema, while the other patient’s implant was redirected into the vitreous chamber with no further anterior migration. The risk of dexamethasone implants migrating into the anterior chamber of vitrectomized eyes and those with sutured IOL implantation should be kept in mind and the patient should be informed and advised to see an ophthalmologist immediately before permanent corneal endothelial damage occurs. © 2020 by Turkish Ophthalmological Association.