Acceptance and Quality Control Tests for the Single Photon Emission Computerized Tomography (SPECT) Gamma Cameras and SPECT/CT Systems; [Tek Foton Emisyon Kompüterize Tomografi (SPECT) Gama Kameralar ve SPECT/BT Sistemleri için Kabul ve Kalite Kontrol Testleri]

dc.contributor.authorDönmez S.
dc.contributor.authorAyan A.
dc.contributor.authorParlak Y.
dc.contributor.authorKovan B.
dc.contributor.authorHiçürkmez M.
dc.contributor.authorKıraç F.S.
dc.contributor.authorDemir M.
dc.contributor.authorToklu T.
dc.contributor.authorHacıosmanoğlu T.
dc.contributor.authorÖzaslan İ.A.
dc.contributor.authorPoyraz L.
dc.contributor.authorve Kalite Kontrol Çalışma Grubu Üyeleri T.R.G.
dc.date.accessioned2024-07-22T08:07:49Z
dc.date.available2024-07-22T08:07:49Z
dc.date.issued2020
dc.description.abstractScintigraphic images play an important role in the diagnosis of diseases by providing accurate clinical information independent of the operator. However, the good quality image may not be obtained due to changes in the performance of the imaging system and/or external factors. A poor quality image will make difficult to interpretate clinical studies. Quality Control (QC) tests provide to reveal the conditions that will adversely affect the image quality before starting of scintigraphic imaging, and to make the necessary arrangements. Although QC tests show relative changes depending on the brand and model of gama camera, there are tests that must be done routinely. For gamma cameras [planar and single photon emission computerized tomography (SPECT)] to be newly installed in the Nuclear Medicine Clinic, “Acceptance Tests” should be carried out after the installation. “Checks before clinical studies” before. © Telif Hakkı 2020 Türkiye Nükleer Tıp Derneği / Nükleer Tıp Seminerleri, Galenos Yayınevi tarafından yayınlanmıştır.
dc.identifier.DOI-ID10.4274/NTS.GALENOS.2020.0007
dc.identifier.issn21496447
dc.identifier.urihttp://akademikarsiv.cbu.edu.tr:4000/handle/123456789/14116
dc.language.isoTurkish
dc.publisherGalenos Publishing House
dc.rightsAll Open Access; Bronze Open Access
dc.subjectArticle
dc.subjectimage quality
dc.subjectiterative reconstruction
dc.subjectquality control
dc.subjectsingle photon emission computed tomography
dc.titleAcceptance and Quality Control Tests for the Single Photon Emission Computerized Tomography (SPECT) Gamma Cameras and SPECT/CT Systems; [Tek Foton Emisyon Kompüterize Tomografi (SPECT) Gama Kameralar ve SPECT/BT Sistemleri için Kabul ve Kalite Kontrol Testleri]
dc.typeArticle

Files