Investigation on the tribology of Zr ion implanted tool steel

dc.contributor.authorAkbas N.
dc.contributor.authorOztarhan A.
dc.contributor.authorMonteiro O.R.
dc.contributor.authorBrown I.G.
dc.date.accessioned2024-07-22T08:25:11Z
dc.date.available2024-07-22T08:25:11Z
dc.date.issued2002
dc.description.abstractAISI D3 tool steel was ion implanted with zirconium and the improvement in surface tribological properties investigated. The Zr ion implantation was done using a metal vapor vacuum arc (Mevva) broad-beam ion source, with a mean ion energy of 130 keV and at doses of 3.6 × 1016, 5 × 1016 and 1 × 1017 ions/cm2. Wear, friction and hardness of the implanted samples were measured and compared to the performance of unimplanted steel. The wear resistance was increased by about a factor of two, the friction remained about the same or was possibly increased by a small amount and the near-surface hardness was improved by a factor of five or more by the ion implantation. We also investigated the effect on the Zr implantation profile of the multi-component energy distribution of the ion beam. © 2002 Elsevier Science B.V. All rights reserved.
dc.identifier.DOI-ID10.1016/S0043-1648(01)00894-8
dc.identifier.issn00431648
dc.identifier.urihttp://akademikarsiv.cbu.edu.tr:4000/handle/123456789/20300
dc.language.isoEnglish
dc.subjection implantation
dc.subjectsteel
dc.subjecttool wear
dc.subjecttribology
dc.subjectzirconium
dc.subjectHardness
dc.subjectPositive ions
dc.subjectTribology
dc.subjectVacuum
dc.subjectVapors
dc.subjectWear of materials
dc.subjectZirconium
dc.subjectNear-surface hardness
dc.subjectSteel
dc.titleInvestigation on the tribology of Zr ion implanted tool steel
dc.typeArticle

Files