Computer Aided Finite Element Simulation of the Developed Driller System for Bone Drilling Process in Orthopedic Surgery

dc.contributor.authorGok K.
dc.contributor.authorGok A.
dc.contributor.authorKisioglu Y.
dc.date.accessioned2024-07-22T08:08:21Z
dc.date.available2024-07-22T08:08:21Z
dc.date.issued2019
dc.description.abstractHeat reveals during the bone drilling operations in orthopedic surgery because of friction between bone and surgical drill bit. The heating causes extremely important damages in bone and soft tissues. The heating has a critical threshold and it is known as 47C. If bone temperature value exceeds 47°C, osteonecrosis occurs in bones and soft tissues. Many factors such as surgical drill bit geometry and material, drilling parameters, coolant has important roles for the temperature rise. Many methods are used to decrease the temperature rise. The most effective method among them is to use the coolant internally. Numeric simulations of a new driller system to avoid the overheating during the orthopedic operating processes were performed in this study. The numerical simulation with/without coolant was also performed using the finite element based software. Computer aided simulation studies were used to measure the bone temperatures occurred during the bone drilling processes. The outcomes from the simulations were compared with the experimental results. A good temperature level agreement between the experimental results and FEA simulations was found during the bone drilling process. © 2019 World Scientific Publishing Company.
dc.identifier.DOI-ID10.1142/S0219686719500318
dc.identifier.issn02196867
dc.identifier.urihttp://akademikarsiv.cbu.edu.tr:4000/handle/123456789/14361
dc.language.isoEnglish
dc.publisherWorld Scientific Publishing Co. Pte Ltd
dc.subjectBits
dc.subjectCell death
dc.subjectComputer software
dc.subjectCoolants
dc.subjectDrilling equipment
dc.subjectDrills
dc.subjectHistology
dc.subjectInfill drilling
dc.subjectOrthopedics
dc.subjectTissue
dc.subjectTransplantation (surgical)
dc.subjectBone drilling
dc.subjectComputer aided simulations
dc.subjectCritical threshold
dc.subjectdriller system
dc.subjectDrilling parameters
dc.subjectFinite element simulations
dc.subjectInternal cooling
dc.subjectNecrosis
dc.subjectFinite element method
dc.titleComputer Aided Finite Element Simulation of the Developed Driller System for Bone Drilling Process in Orthopedic Surgery
dc.typeArticle

Files