The assessment of placental volume and mean gray value in preeclamptic placentas by using three-dimensional ultrasonography

dc.contributor.authorArtunc Ulkumen B.
dc.contributor.authorPala H.G.
dc.contributor.authorUyar Y.
dc.contributor.authorKoyuncu F.M.
dc.contributor.authorBulbul Baytur Y.
dc.date.accessioned2024-07-22T08:13:17Z
dc.date.available2024-07-22T08:13:17Z
dc.date.issued2015
dc.description.abstractObjectives: We aimed to evaluate the placental volume and placental mean gray value in preeclampsia and healthy placentas by using three-dimensional (3D) ultrasonography and Virtual Organ Computer-aided AnaLysis (VOCAL). Methods: This case-control prospective study consisted of 27 singleton pregnancies complicated by preeclampsia and 54 healthy singleton pregnancies matched for gestational age, maternal age and parity. Placental volume and placental volumetric mean gray values were evaluated. The placental volume (cm) was analyzed using the VOCAL imaging program, and 3D histogram was used to calculate the volumetric mean gray value (%). Results: Preeclamptic and control group consisted of 27 (mean age: 28.90±5.95 years, mean gestation: 32.0±4.55 weeks) and 54 (mean age: 29.48±5.78 years, mean gestation: 32.61±4.23 weeks) singleton pregnancies, respectively. Placental volume was significantly smaller in preeclampsia (250.62±91.69 versus 370.98±167.82cm; p=0.001). Volumetric mean gray value of the placenta was significantly higher in preeclampsia (38.24±8.41 versus 33.50±8.90%; p=0.043). Placental volume was significantly correlated with the estimated fetal weight (r=0.319; p=0.003). There was negative significant relation between placental volume and umbilical artery pulsatility index, resistance index and systolic/diastolic ratio (r=-0.244, p=0.024; r=-0.283, p=0.005; r=-0.241, p=0.024, respectively). Conclusions: Placental volume diminishes significantly in preeclampsia, whereas volumetric mean gray values increases. This may reflect the early alterations in preeclamptic placentas, which may help to understand the pathophysiology better. © 2014 Informa UK Ltd. All rights reserved: reproduction in whole or part not permitted.
dc.identifier.DOI-ID10.3109/14767058.2014.944156
dc.identifier.issn14767058
dc.identifier.urihttp://akademikarsiv.cbu.edu.tr:4000/handle/123456789/16316
dc.language.isoEnglish
dc.publisherInforma Healthcare
dc.subjectAdult
dc.subjectCase-Control Studies
dc.subjectFemale
dc.subjectHumans
dc.subjectImaging, Three-Dimensional
dc.subjectOrgan Size
dc.subjectPlacenta
dc.subjectPre-Eclampsia
dc.subjectPregnancy
dc.subjectProspective Studies
dc.subjectUltrasonography, Prenatal
dc.subjectYoung Adult
dc.subjectadult
dc.subjectArticle
dc.subjectcase control study
dc.subjectclinical article
dc.subjectcontrolled study
dc.subjectdisease association
dc.subjectechography
dc.subjectfemale
dc.subjectfetus weight
dc.subjectgestational age
dc.subjecthistogram
dc.subjecthuman
dc.subjectimage analysis
dc.subjectinformation processing
dc.subjectmaternal age
dc.subjectoutcome assessment
dc.subjectparameters
dc.subjectparity
dc.subjectphysical parameters
dc.subjectplacenta weight
dc.subjectplacental volumetric mean gray value
dc.subjectpreeclampsia
dc.subjectpregnancy
dc.subjectpriority journal
dc.subjectprospective study
dc.subjectresistance index
dc.subjectsystolic diastolic ratio
dc.subjectthree dimensional echography
dc.subjectumbilical artery pulsality index
dc.subjectvirtual organ computer aided anaLysis
dc.subjectvolumetry
dc.subjectfetus echography
dc.subjectorgan size
dc.subjectplacenta
dc.subjectpreeclampsia
dc.subjectthree dimensional imaging
dc.subjectyoung adult
dc.titleThe assessment of placental volume and mean gray value in preeclamptic placentas by using three-dimensional ultrasonography
dc.typeArticle

Files