Exergoeconomic analysis of an underground air tunnel system for greenhouse cooling system

dc.contributor.authorOzgener O.
dc.contributor.authorOzgener L.
dc.date.accessioned2024-07-22T08:20:50Z
dc.date.available2024-07-22T08:20:50Z
dc.date.issued2010
dc.description.abstractThis paper investigates some exergoeconomic parameters for an underground air tunnel system based upon some operating conditions. The ratio of exergy loss rate to capital cost (Rex) changes between 0.052 and 0.552. The total exergy losses values are obtained to be from 0.26 kW to 2.50 kW for the system. The daily average maximum cooling coefficient of performances (COP) values for the system are also obtained to be 11.96 for experimental period, while the total average COP is found to be 5.89. The overall exergy efficiency value for the system on a product/fuel basis is found to be 56.9%. © 2010 Elsevier Ltd and IIR. All rights reserved.
dc.identifier.DOI-ID10.1016/j.ijrefrig.2010.02.008
dc.identifier.issn01407007
dc.identifier.urihttp://akademikarsiv.cbu.edu.tr:4000/handle/123456789/18352
dc.language.isoEnglish
dc.subjectCooling
dc.subjectGreenhouses
dc.subjectHeat exchangers
dc.subjectCapital costs
dc.subjectCoefficient of performance
dc.subjectEnergy
dc.subjectEnergy recovery
dc.subjectExergoeconomic analysis
dc.subjectExergy efficiencies
dc.subjectExergy loss
dc.subjectGreenhouse cooling
dc.subjectMaximum cooling
dc.subjectOperating condition
dc.subjectSystem-based
dc.subjectExergy
dc.titleExergoeconomic analysis of an underground air tunnel system for greenhouse cooling system
dc.typeArticle

Files