Optimization of counter flow Ranque-Hilsch vortex tube performance using Taguchi method

dc.contributor.authorPinar A.M.
dc.contributor.authorUluer O.
dc.contributor.authorKirmaci V.
dc.date.accessioned2024-07-22T08:21:39Z
dc.date.available2024-07-22T08:21:39Z
dc.date.issued2009
dc.description.abstractThis study discusses the application of Taguchi method in assessing maximum temperature gradient for the Ranque-Hilsch counter flow vortex tube performance. The experiments were planned based on Taguchi's L27 orthogonal array with each trial performed under different conditions of inlet pressure, nozzle number and fluid type. Signal-to-noise ratio (S/N) analysis, analysis of variance (ANOVA) and regression analysis were carried out in order to determine the effects of process parameters and optimal factor settings. Finally, confirmation tests verified that Taguchi method achieved optimization of counter flow Ranque-Hilsch vortex tube performance with sufficient accuracy. © 2009 Elsevier Ltd and IIR.
dc.identifier.DOI-ID10.1016/j.ijrefrig.2009.02.018
dc.identifier.issn01407007
dc.identifier.urihttp://akademikarsiv.cbu.edu.tr:4000/handle/123456789/18713
dc.language.isoEnglish
dc.subjectCapillary tubes
dc.subjectOptimization
dc.subjectRefrigerating machinery
dc.subjectRefrigeration
dc.subjectRefrigerators
dc.subjectRegression analysis
dc.subjectSignal to noise ratio
dc.subjectTaguchi methods
dc.subjectTubes (components)
dc.subjectVortex flow
dc.subjectConfirmation test
dc.subjectCounter-flows
dc.subjectInlet pressures
dc.subjectMaximum temperature gradient
dc.subjectOrthogonal array
dc.subjectPerformance
dc.subjectProcess parameters
dc.subjectRanque-Hilsch
dc.subjectRanque-Hilsch vortex tube
dc.subjectRefrigeration system
dc.subjectTaguchi
dc.subjectVortex tube
dc.subjectAnalysis of variance (ANOVA)
dc.titleOptimization of counter flow Ranque-Hilsch vortex tube performance using Taguchi method