Skip to main content
English
Català
Čeština
Deutsch
Español
Français
Gàidhlig
Italiano
Latviešu
Magyar
Nederlands
Polski
Português
Português do Brasil
Srpski (lat)
Suomi
Svenska
Türkçe
Tiếng Việt
Қазақ
বাংলা
हिंदी
Ελληνικά
Српски
Yкраї́нська
Log In
Email address
Password
Log in
Have you forgotten your password?
Communities & Collections
All Contents
Statistics
English
Català
Čeština
Deutsch
Español
Français
Gàidhlig
Italiano
Latviešu
Magyar
Nederlands
Polski
Português
Português do Brasil
Srpski (lat)
Suomi
Svenska
Türkçe
Tiếng Việt
Қазақ
বাংলা
हिंदी
Ελληνικά
Српски
Yкраї́нська
Log In
Email address
Password
Log in
Have you forgotten your password?
Home
Araştırma Çıktıları | Web Of Science
Web of Science Koleksiyonu
English
English
No Thumbnail Available
Date
Authors
Bakicierler, G
Sisman, G
Akgungor, K
Journal Title
Journal ISSN
Volume Title
Publisher
0035-001X
Abstract
SOC MEXICANA FISICA
Description
Keywords
Metal artifacts cause errors in the exact delineation of implants and dose changes in radiotherapy. In this study, the dose distribution differences in the region of interest (ROI) were calculated by deliberately making contouring errors from the real size of model implants by using both Monaco treatment planning system (TPS) and Geant4 toolkit. In Sec. 2, the computed tomography images were acquired by placing known uniform cylindrical geometry titanium (Ti6Al4V) and cobalt (CoCrMo) alloys into water phantoms separately. The metal alloys were artificially contoured as 2 mm contracted and expanded from their real dimensions in Monaco TPS. The plans were generated with 6 MV photon beams for contouring of three different sizes, real, contracted and expanded, for each metal alloy. In addition, all configurations were simulated in Geant4 by using the photon energy spectrum data of the Elekta Synergy linear accelerator. Then, the 3D dose data obtained from ROIs near the implant in Monaco TPS and Geant4 were analyzed with in-house programs. In Sec. 3, the depth dose values of Geant4 were compatible with TPS calculations and ion chamber measurements. When the alloys were contoured to real dimensions, it was observed that the local isodose values have changed up to 15% in ROI. The mean dose values were found to be higher in contracted and lower in expanded contours. It was observed that +/- 2 mm error in contouring the implants changed the mean dose up to +/- 8%. In Sec. 4, this study emphasized that a few millimeters of error in contouring different implant materials can have a significant effect on dose distribution in a region close to the implant.
Citation
URI
http://akademikarsiv.cbu.edu.tr:4000/handle/123456789/7439
Collections
Web of Science Koleksiyonu
Full item page