Displacement and stress distribution of Kilroy spring and nickel-titanium closed-coil spring during traction of palatally impacted canine: A 3-dimensional finite element analysis

dc.contributor.authorSezici, YL
dc.contributor.authorGediz, M
dc.contributor.authorAkis, AA
dc.contributor.authorSari, G
dc.contributor.authorDuran, GS
dc.contributor.authorDindaroglu, F
dc.date.accessioned2024-07-18T12:03:50Z
dc.date.available2024-07-18T12:03:50Z
dc.description.abstractObjective To compare the stress distribution and initial displacements during traction of palatally impacted canine between Kilroy and nickel-titanium (NiTi) closed-coil springs by means of the finite element analysis. Setting and Sample Population A finite element method analysis of two traction methods for a maxillary impacted canine. Materials and Methods The corresponding periodontal ligaments (PDLs), brackets, molar tubes and a 0.019 x 0.025-in base stainless-steel (SS) wire were modelled and imported to ANSYS SpaceClaim version 2020 R1. Traction was simulated under two different set-ups with equal force magnitude (60 g); (1) the Kilroy spring, which is made of 0.016-inch SS, and (2) the NiTi closed-coil spring. Von Mises stress distributions and initial displacements of the maxillary teeth were analysed. Results In both mechanics, while the highest stress was seen on the impacted canine (Kilroy, 10.41 kPa; NiTi closed-coil, 5.27 kPa), the stress distribution decreased as the distance from the impacted canine increased. The Kilroy spring showed a greater total displacement (465.60 mu m) on the impacted canine. The higher stresses on the adjacent lateral (5.29 kPa) and premolar (6.41 kPa) occurred with the Kilroy spring. Conclusions The Kilroy spring yielded higher stresses than the NiTi closed-coil spring on the impacted canine and the adjacent teeth. The difference between distribution of the stresses over the impacted canine induced greater displacement with the Kilroy spring, particularly in the vertical direction.
dc.identifier.issn1601-6335
dc.identifier.other1601-6343
dc.identifier.urihttp://akademikarsiv.cbu.edu.tr:4000/handle/123456789/9377
dc.language.isoEnglish
dc.publisherWILEY
dc.subjectPERIODONTAL-LIGAMENT
dc.subjectROOT RESORPTION
dc.subjectMAXILLARY
dc.subjectFORCE
dc.subjectEXTRUSION
dc.subjectMECHANICS
dc.subjectINTRUSION
dc.subjectBEHAVIOR
dc.subjectTEETH
dc.subjectBONE
dc.titleDisplacement and stress distribution of Kilroy spring and nickel-titanium closed-coil spring during traction of palatally impacted canine: A 3-dimensional finite element analysis
dc.typeArticle

Files