Comparison on Dynamic Performance of CBFs Designed as per TEC2007 and TEC2018

dc.contributor.authorBozkurt, MB
dc.contributor.authorSerin, B
dc.date.accessioned2024-07-18T11:47:02Z
dc.date.available2024-07-18T11:47:02Z
dc.description.abstractIn this study, dynamic performance of six chevron and split-X braced concentrically braced frames (CBFs) having 3, 6 and 9 number of stories designed as per Turkish Seismic Code 2007 (TSC-2007) and Turkish Seismic Code for Buildings 2018 (TSCB- 2018) were compared. By using Opensees software, a total of 1056 nonlinear time history analyses was conducted under 44 far-field ground motions scaled based on TSC-2007 and TSCB-2018 by considering maximum considered earthquake having a 2% probability of being exceeded in 50 years. The results indicate that the archetypes designed as per TSCB-2018 are more reliable in CBFs employing both chevron and split-X brace configuration.
dc.identifier.issn1300-3453
dc.identifier.urihttp://akademikarsiv.cbu.edu.tr:4000/handle/123456789/3206
dc.language.isoTurkish
dc.publisherTURKISH CHAMBER CIVIL ENGINEERS
dc.subjectCONCENTRICALLY BRACED FRAMES
dc.subjectSEISMIC RESPONSE
dc.subjectSTEEL BRACES
dc.subjectBEHAVIOR
dc.subjectMEMBERS
dc.subjectCYCLES
dc.titleComparison on Dynamic Performance of CBFs Designed as per TEC2007 and TEC2018
dc.typeArticle

Files