Tribological behaviour of plasma immersion ion implanted AISI 304 stainless steel against polymer and ceramic counterfaces

dc.contributor.authorSaklakoglu, N
dc.contributor.authorSaklakoglu, IE
dc.contributor.authorCeyhun, V
dc.contributor.authorAgaçhan, N
dc.contributor.authorShort, KT
dc.contributor.authorCollins, GA
dc.date.accessioned2024-07-18T12:03:00Z
dc.date.available2024-07-18T12:03:00Z
dc.description.abstractType 304 austenitic stainless steel samples were implanted with nitrogen using plasma immersion ion implantation (PIII) at different temperatures between 350 and 500 degrees C. Treated and untreated samples have been studied by wear-friction testing, microhardness measurement and scanning electron microscopy ( SEM). The experimental results indicated that the hardness and wear resistance is improved by increasing the penetration depth of nitrogen, whereas the friction coefficient is significantly increased by PIII.
dc.identifier.issn0267-0844
dc.identifier.other1743-2944
dc.identifier.urihttp://akademikarsiv.cbu.edu.tr:4000/handle/123456789/8834
dc.language.isoEnglish
dc.publisherTAYLOR & FRANCIS LTD
dc.subjectAUSTENITIC STAINLESS-STEEL
dc.subjectSURFACE MODIFICATION
dc.subjectEXPANDED AUSTENITE
dc.subjectNITROGEN
dc.subjectCARBON
dc.titleTribological behaviour of plasma immersion ion implanted AISI 304 stainless steel against polymer and ceramic counterfaces
dc.typeArticle

Files